Acceptance inspection of a new house in Nowa Wieś
Scope of work:Thermal imaging under induced negative pressure
Location: Nowa Wieś, Kuyavian-Pomeranian Voivodeship
The survey helped identify air leakage points in the building. The findings documented issues around window installation and discontinuities in the insulation for discussion with the contractor.
Inspection of electrical installations at a chewing-gum factory
Scope of work:Fire-prevention thermal imaging inspection of electrical installations
Location: Skarbimierz, Opole Voivodeship
The inspection was carried out in an operating production building to support the technical documentation required by the insurer. Measurements followed the VdS 2860 and DIN 54191 guidelines.
Locating a domestic hot-water leak near Gniezno
Scope of work:Locating a leak in the domestic hot-water system
Location: Dziekanowice, Greater Poland Voivodeship
Thermal imaging indicated the probable location of the leak and narrowed the area that needed to be opened during the repair.
Quality inspection of a hospital building in Kraków
Scope of work:Thermal imaging and airtightness tests in selected rooms
Location: Kraków, Lesser Poland Voivodeship
Selected rooms in the new hospital complex were examined to assess envelope performance against the project assumptions, including conditions relevant to indoor air hygiene.
Insulation damage in a house in Kraków
Scope of work:Locating attic insulation damaged by martens
Location: Kraków, Lesser Poland Voivodeship
The thermal imaging survey showed the scale of the damage and identified areas where the thermal insulation was missing or discontinuous.
New office building in Gdańsk — BREEAM 2016
Scope of work:Thermal imaging assessment supporting the BREEAM 2016 certification process
Location: Gdańsk, Pomeranian Voivodeship
The survey covered envelope junctions, window and door installation, and thermal bridges. The findings were included in the project documentation prepared for the certification process.
Recurring dampness in a house in Kraków
Scope of work:Assessing conditions associated with mould growth
Location: Kraków, Lesser Poland Voivodeship
Thermal imaging was used to examine temperature patterns in the affected areas and identify partitions that required further assessment or insulation work.
Inspection of a photovoltaic farm near Białystok
Scope of work:Routine thermal imaging inspection of photovoltaic panels
Location: near Białystok, Podlaskie Voivodeship
The inspection identified hot spots and other thermal anomalies that could be prioritised for maintenance.
Inspection of insulation work in municipal schools in Pabianice
Scope of work:Quality assessment of recently installed insulation
Location: Pabianice, Łódź Voivodeship
Thermal imaging surveys were carried out in 11 educational buildings. The results were used to review the recent insulation work and assess thermal performance at selected building-envelope details.
Mapping underfloor heating pipes in a Kraków flat
Scope of work:Locating the route of an underfloor heating system
Location: Kraków, Lesser Poland Voivodeship
Thermal imaging was used to map the pipe route before renovation work, reducing the risk of accidental damage.
Fire-prevention thermal imaging inspection of an electrical installation
Scope of work:Thermal imaging inspection of an electrical installation
Location: Wieliczka, Lesser Poland Voivodeship
The inspection identified overheating at the connections of a 400 A main-switch contactor. The recorded contactor temperature reached 160 °C and required technical attention.
Fire-prevention thermal imaging inspection of machinery
Scope of work:Thermal imaging inspection of electrical machinery
Location: Kraków, Lesser Poland Voivodeship
The inspection identified mechanical irregularities associated with motor friction and a conveyor fault.
Fire-prevention thermal imaging inspection of an electrical installation
Scope of work:Thermal imaging inspection of an electrical installation
Location: Rzeszów, Subcarpathian Voivodeship
The inspection identified overheating at an FTC 38503 Cu/Al distribution-block connection on the L1 supply phase. The temperature reached 200 °C at a measured load of 20 A.
Indoor air quality assessment in a building
Scope of work:Material sampling and laboratory analysis for polycyclic aromatic hydrocarbons (PAHs)
Location: Warsaw, Masovian Voivodeship
A sample of floor construction material was collected for qualitative laboratory analysis. Anthracene was detected in the sample.
Indoor air quality assessment in a school
Scope of work:Material sampling and laboratory analysis
Location: Piła, Greater Poland Voivodeship
A floor material sample was collected for laboratory analysis. The reported concentration of harmful compounds exceeded the reference value used for PAHs, indicating that the surface layers did not form an effective barrier to emissions.
Acoustic measurements in a building
Scope of work:Airborne sound insulation measurements and acoustic-leak localisation
Location: Warsaw
The external partition was tested for airborne sound insulation, and an acoustic camera was used to locate weak points. The results indicated that the tested partition met the applicable requirements for the measured scope.
Acoustic measurements in a building
Scope of work:Airborne sound insulation measurements
Location: Świnoujście, West Pomeranian Voivodeship
The calculated apparent sound reduction indices indicated that the tested partition provided insufficient airborne sound insulation.
Locating heat loss with a thermal imaging camera
Scope of work:Thermal imaging survey of a building
Location: Warsaw, Masovian Voivodeship
The survey identified areas of heat loss, with window installation emerging as the main issue. The TERMOCENT report supported the client’s discussion with the installation contractor.
Locating a continuous high-frequency sound with an acoustic camera
Scope of work:Locating the source of a persistent sound
Location: Kraków, Lesser Poland Voivodeship
An acoustic-camera measurement was carried out in a flat affected by a persistent high-frequency sound. The source was traced to evacuation signs equipped with an acoustic warning system.
Locating heat loss with a thermal imaging camera
Scope of work:Thermal imaging survey of a building
Location: Marysin, Lublin Voivodeship
The survey identified heat-loss areas associated with glazing-unit defects and discontinuities in the thermal insulation. It also showed insulation damage caused by a marten. The report documented the locations requiring attention.
How ventilation performance affects recurring mould
Scope of work:Thermal imaging and assessment of indoor physical conditions
The client reported recurring mould in wall corners despite regular airing and repeated removal. The assessment indicated that low internal-surface temperatures and local condensation, rather than ventilation alone, were contributing to the problem.
Using a blower door to locate air leaks
Scope of work:Thermal imaging under an induced pressure difference
A standard visual inspection did not reveal the source of the draughts. Thermal imaging performed at an induced negative pressure of 70 Pa identified leaks in the wind barrier and discontinuities at building-envelope junctions. The report was used to plan targeted repairs.
FORUM GLIWICE SHOPPING CENTRE
A shopping and entertainment centre in central Gliwice with an area of approximately 50,000 m2. TERMOCENT carried out:
- a thermal imaging survey,
- an airtightness test.
WAWEL CATHEDRAL
The Cathedral Basilica of St Stanislaus and St Wenceslaus on Wawel Hill. TERMOCENT carried out:
- a thermal imaging survey.
WIELICZKA SALT MINE
A UNESCO World Heritage site inscribed on the original World Heritage List in 1978. TERMOCENT carried out:
- an indoor air quality assessment.
NORBLIN FACTORY
A mixed-use complex with offices, food, entertainment, retail and services, covering approximately 65,000 m2. TERMOCENT carried out:
- a thermal imaging survey,
- an airtightness test,
- an indoor air quality assessment,
- smoke-based leak localisation,
- a watertightness test.
BROWARY WARSZAWSKIE
A mixed-use complex combining office and residential space with food and service areas, covering approximately 100,000 m2. TERMOCENT carried out:
- a thermal imaging survey,
- acoustic measurements,
- an indoor air quality assessment.
ZALANDO LOGISTICS FACILITY
A ZALANDO logistics centre in Bydgoszcz with an approximate volume of 1.5 million m3. TERMOCENT carried out:
- an indoor air quality assessment,
- an airtightness test.