{"id":2956,"date":"2022-10-28T09:56:47","date_gmt":"2022-10-28T07:56:47","guid":{"rendered":"https:\/\/termocent.com\/2022\/10\/28\/what-does-a-thermal-imaging-survey-look-like\/"},"modified":"2022-10-28T09:56:47","modified_gmt":"2022-10-28T07:56:47","slug":"what-does-a-thermal-imaging-survey-look-like","status":"publish","type":"post","link":"https:\/\/termocent.com\/en\/blog\/what-does-a-thermal-imaging-survey-look-like\/","title":{"rendered":"What does a thermal imaging survey look like?"},"content":{"rendered":"<p><img decoding=\"async\" class=\"alignnone wp-image-2423\" src=\"https:\/\/termocent.com\/wp-content\/uploads\/2019\/03\/Baner-2-1.jpg\" alt=\"\" width=\"1100\" height=\"328\" srcset=\"https:\/\/termocent.com\/wp-content\/uploads\/2019\/03\/Baner-2-1.jpg 1899w, https:\/\/termocent.com\/wp-content\/uploads\/2019\/03\/Baner-2-1-300x89.jpg 300w, https:\/\/termocent.com\/wp-content\/uploads\/2019\/03\/Baner-2-1-1024x305.jpg 1024w, https:\/\/termocent.com\/wp-content\/uploads\/2019\/03\/Baner-2-1-768x229.jpg 768w, https:\/\/termocent.com\/wp-content\/uploads\/2019\/03\/Baner-2-1-1536x458.jpg 1536w\" sizes=\"(max-width: 1100px) 100vw, 1100px\" \/><\/p>\n<p>A thermal imaging survey can be arranged before or after the planned insulation of buildings to <strong>inspect the condition and quality of the service performed<\/strong>, as well as at the stage of construction work when creating new buildings. In any situation where you want to check where heat is escaping from a building and accurately determine damage, as well as structural defects, it is necessary to <strong>use professional equipment<\/strong> adapted to such activities. <\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_88 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Spis tre\u015bci<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/termocent.com\/en\/blog\/what-does-a-thermal-imaging-survey-look-like\/#Process_stages_of_thermal_imaging_survey\" >Process (stages) of thermal imaging survey<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/termocent.com\/en\/blog\/what-does-a-thermal-imaging-survey-look-like\/#What_is_a_thermal_imaging_survey_used_for\" >What is a thermal imaging survey used for?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/termocent.com\/en\/blog\/what-does-a-thermal-imaging-survey-look-like\/#How_to_check_the_quality_of_the_test_performed\" >How to check the quality of the test performed<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Process_stages_of_thermal_imaging_survey\"><\/span>Process (stages) of thermal imaging survey<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Thermal imaging diagnostics<\/strong> is preceded by a discussion with the client about his expectations and the selection of the scope of tests to provide the best possible price offer. Then a suitable date is set. Thermal imaging of a building is best carried out during the heating season, when there is a suitable difference in temperature between outside and inside the premises.  <\/p>\n<p>If the conditions are less favorable, this is taken into account when interpreting the results, so the timing of the study is adapted to the demand of customers. Each case requires an individual approach, do not wait, it is worth contacting <strong>a professional company<\/strong> as soon as possible to implement an appropriate action plan. Specialists with the help of a thermal imaging camera will take measurements and provide preliminary conclusions.  <\/p>\n<p>Thanks to the fact that<strong> high-tech equipment<\/strong> is used, all significant faults, defects and anomalies occurring in the objects under investigation are localized. On the basis of the results, while still under investigation, a preliminary assessment is presented with an indication of how to solve the problem. The elaboration of the results includes the necessary documentation in the form of thermograms, i.e. records of thermal images and optical photographs with commentary.  <\/p>\n<p>The extended report on the causes of mold and mildew, heat loss, or <strong>risk assessment<\/strong> also includes calculations and compilations with standards and legal regulations. The thermal transmittance value for partitions and temperature coefficient for thermal bridges are also listed. You can order a basic or extended report.  <\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_is_a_thermal_imaging_survey_used_for\"><\/span>What is a thermal imaging survey used for?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>By carrying out a thermal imaging survey, it is possible to evaluate both private buildings and commercial buildings and various types of businesses. Thanks to the measurements, <strong>energy efficiency<\/strong> is checked, places of heat loss are located, construction work is assessed, sources of mold and mildew appearance are diagnosed and the risk of their occurrence is determined, leaks are found. <\/p>\n<p>Measurements are also used to inspect the installation of window and door frames. <strong>Thermal<\/strong> imaging is helpful in improving the insulation and airtightness of cold stores, freezers and air-conditioned rooms. Thermal imaging <strong>testing<\/strong> is useful not only for assessing the condition of a building, but also for non-contact inspection of electrical systems in factories, industrial equipment and processes. Thermal imaging services are also useful in veterinary medicine. <\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_to_check_the_quality_of_the_test_performed\"><\/span>How to check the quality of the test performed<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Using a professional company that specializes in conducting thermal imaging surveys is a guarantee of a well-executed service. TERMOCENT&#8217;s employees have specialized equipment and have <strong>the necessary qualifications<\/strong>, licenses and directional education. The surveys are complied with by a person with qualifications in accordance with ISO 18436-7:2008.  <\/p>\n<p>The best recommendation for professionals are numerous recommendations and a group of satisfied customers. <strong>Specialized knowledge and extensive experience of<\/strong> employees, as well as high-quality equipment allows to provide services at the highest level.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">Feel free to contact us to discuss in detail any issues of interest to you.<\/p>\n<p style=\"text-align: center;\"><strong>+48 530 105 398<\/strong><\/p>\n<p style=\"text-align: center;\"><strong>kontakt@termocent.com<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A thermal imaging survey can be arranged before or after the planned insulation of buildings to inspect the condition and quality of the service performed, as well as at the stage of construction work when creating new buildings. In any situation where you want to check where heat is escaping from a building and accurately [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[23],"tags":[],"class_list":["post-2956","post","type-post","status-publish","format-standard","hentry","category-articles"],"acf":[],"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/termocent.com\/en\/wp-json\/wp\/v2\/posts\/2956","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/termocent.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/termocent.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/termocent.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/termocent.com\/en\/wp-json\/wp\/v2\/comments?post=2956"}],"version-history":[{"count":0,"href":"https:\/\/termocent.com\/en\/wp-json\/wp\/v2\/posts\/2956\/revisions"}],"wp:attachment":[{"href":"https:\/\/termocent.com\/en\/wp-json\/wp\/v2\/media?parent=2956"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/termocent.com\/en\/wp-json\/wp\/v2\/categories?post=2956"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/termocent.com\/en\/wp-json\/wp\/v2\/tags?post=2956"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}